Lab Report Example: 3 Complete Annotated Lab Reports (Chemistry, Biology, Physics) with Format and Template
Three complete, annotated lab report examples: high-school chemistry (reaction rate vs. temperature), intro biology (catalase activity vs. pH) and physics (pendulum period vs. length). Each has a title, abstract, introduction with hypothesis, methods, results table, discussion with error analysis, conclusion and real references. Plus the standard lab report format and a fill-in template.
A good lab report example teaches you more than a page of rubric bullet points, as long as you read it the way your teacher grades it. Most examples online are either fragments (“here is a sample hypothesis”) or finished reports with no explanation of why each section looks the way it does. This guide gives you both. First the standard lab report format and the conventions teachers actually mark you on, then annotated fragments of the hardest sections, then three complete lab reports: a high-school chemistry report on reaction rate and temperature, an intro biology report on catalase and pH, and a physics report on the period of a pendulum. Each one ends with a short “Why it works” note. At the end you will find a fill-in lab report template, a table of experiments that work well for a first report, and answers to the questions students ask most.
One thing to say up front: all the measurements in the three examples are sample data for illustration. They are physically plausible and the math is internally consistent (you can recompute every average, rate and percent error), but they were not taken in a real lab. Your report has to be built on the numbers you measured yourself. That is the whole point of a lab report.
What a lab report is (and what it is not)
A lab report is a structured record of an experiment: what question you asked, what you did, what you measured, and what the measurements mean. It is a cousin of the general school report described in our guide on how to write a report, but with a much stricter format, because science writing has to let another person check your work and, ideally, repeat it.
| Lab report | General research report | Essay | |
|---|---|---|---|
| Starting point | Your own experiment and data | Published sources | A question or thesis |
| Main job | Report and interpret measurements | Organize and explain information | Argue a position |
| Structure | Fixed sections (IMRaD) | Flexible headed sections | Introduction, body, conclusion |
| Evidence | Your data, compared with theory | Cited sources | Cited sources and reasoning |
| Voice | Impersonal, precise, past tense for what you did | Neutral, informative | Can be personal |
The fixed structure most teachers use is a version of IMRaD: Introduction, Methods, Results and Discussion, usually with a title and abstract in front and a conclusion and references at the end. Some high schools use a shorter “Purpose, Hypothesis, Materials, Procedure, Data, Analysis, Conclusion” layout. The content is the same; only the labels change. If your teacher hands out a template, use theirs.
The standard lab report format, section by section
| Section | What it answers | Typical length (HS / intro college) | Tense |
|---|---|---|---|
| Title | What was tested? | One line | n/a |
| Abstract | What did you do, find and conclude? | 100–200 words | Past (methods, results), present (conclusion) |
| Introduction | Why does this matter, what theory applies, what do you predict? | 1–3 paragraphs | Present for theory, future or conditional for hypothesis |
| Materials and Methods | What exactly did you do? | Short list plus a paragraph or numbered steps | Past |
| Results | What did you measure? | Table(s), graph(s), 1–2 paragraphs of description | Past |
| Discussion | What do the results mean, how reliable are they? | 3–6 paragraphs | Past for your results, present for accepted theory |
| Conclusion | Was the hypothesis supported? | 3–5 sentences | Past and present |
| References | Where did the theory come from? | 2–5 sources | n/a |
The conventions teachers actually grade
Tense. Describe what you did and what you observed in the past tense (“The solution was heated to 40 °C”; “The disc rose in 13.3 s”). Describe established science in the present tense (“Enzymes denature at extreme pH”). Students lose points for writing the procedure as instructions (“Heat the solution”). A lab report is a record, not a recipe.
Passive or active voice. The traditional rule was “always passive” (“The mass was measured”). Many scientists and style guides now accept active voice with “we” or “I” (“We measured the mass”), because it is shorter and clearer. There is no single correct answer here: follow your teacher’s preference. If you do not know it, use the passive in Methods and mix in the active elsewhere, which is what most textbook examples do. What never works is switching voice mid-paragraph.
Units and significant figures. Every number gets a unit, written with a space (25.0 °C, 0.15 M, 9.77 m/s²). Report measurements to the precision of the instrument: a stopwatch read to 0.01 s does not justify a time of 13.2847 s. Use SI units unless the lab handout says otherwise.
Tables and figures. Tables get a number and a title above them (“Table 1. Time for the cross to disappear at five temperatures”). Graphs and images are figures, with a number and a caption below them. Put the independent variable (the one you changed) on the x-axis and the dependent variable (the one you measured) on the y-axis. Label both axes with quantity and unit. Every table and figure must be mentioned in the text (“As Table 1 shows…”).
Raw versus processed data. Show the individual trials and the averages, not just the averages. Your teacher wants to see the spread, because it tells you how reliable the result is.
What not to include. No “I had fun” or “our group worked well”. No results in the Methods section, no new data in the Discussion, no interpretation in the Results beyond simple description.
Annotated fragments: the four sections students get wrong
Before the full reports, here are the four sections that cause the most trouble, each with a short example and a note on what makes it work.
Fragment 1: a testable hypothesis
If the temperature of the sodium thiosulfate solution is increased from 20 °C to 60 °C, then the time taken for the sulfur precipitate to hide the cross will decrease, because a higher temperature gives more particles enough energy to react when they collide.
Why it works: It names the independent variable (temperature) and its range, the dependent variable (time for the cross to disappear) and the direction of the change, and it gives a scientific reason. The “If… then… because…” frame is not compulsory, but it forces all three parts in. A hypothesis is not a question and not a guess about whether the lab will “work”. If you are unsure how a hypothesis differs from a research question, see research questions vs. hypotheses.
Fragment 2: a Methods paragraph someone could repeat
A 6 mm hole punch was used to cut filter-paper discs. Each disc was soaked in potato extract for 10 s, drained on a paper towel for 5 s and dropped into a beaker containing 10 mL of 3% hydrogen peroxide and 10 mL of buffer. A stopwatch was started when the disc touched the bottom of the beaker and stopped when it reached the surface.
Why it works: Quantities, times and the exact start and stop points are all stated, so another student could repeat the measurement. The start and stop rule matters most: “time how long it takes to float” is ambiguous; “from touching the bottom to reaching the surface” is not.
Fragment 3: describing results without interpreting them
The mean time for the disc to rise was shortest at pH 7 (13.3 s) and increased in both directions, to 24.8 s at pH 5 and 20.6 s at pH 9. At pH 3 and pH 11 the mean times were 61.1 s and 49.1 s. The spread between trials was largest at the two extreme pH values (6.4 s and 7.3 s).
Why it works: It reports the pattern, the extreme values and the variability, and stops. The explanation (denaturation, active site shape) belongs in the Discussion. Our post on how to write a results chapter applies the same rule to longer papers.
Fragment 4: error analysis that is actually analysis
The largest source of random error was human reaction time in starting and stopping the stopwatch, estimated at about 0.2 s per reading. Timing ten oscillations instead of one reduced this to about 0.02 s per period. A systematic error was also present: the release angle of about 10° makes the true period slightly longer than the small-angle formula predicts, by roughly 0.2%, which would make the calculated value of g about 0.4% too low. This matches the size and direction of the difference observed.
Why it works: It separates random from systematic error, estimates the size of each, and checks whether the error explains the actual result. Weak error analysis lists “human error” and stops. Strong error analysis names the error, says which way it pushes the result, and says roughly how much.
Three complete lab report examples
The reports below follow the full IMRaD format. They are written at the level of a strong high-school or first-year college report, roughly 900 to 1,300 words each. In a real report you would also include your graph as an image; here, because this is a web page, each Results section describes in words what the graph shows. Remember: all data below are sample data for illustration.
Example A: Chemistry lab report (high school), reaction rate vs. temperature
Level: high school chemistry (honors or general), also fine for an intro college lab. Experiment: the “disappearing cross” reaction between sodium thiosulfate and hydrochloric acid.
Title
The Effect of Temperature on the Rate of Reaction Between Sodium Thiosulfate and Hydrochloric Acid
Abstract
This experiment investigated how temperature affects the rate of the reaction between sodium thiosulfate and hydrochloric acid. The reaction produces solid sulfur, which gradually makes the solution cloudy. The time taken for a cross drawn under the flask to disappear from view was measured at five temperatures between 20 °C and 60 °C, with three trials at each temperature. The mean time fell from 69.7 s at 20 °C to 5.9 s at 60 °C, and the relative rate (1000/t) rose from 14.3 to 169.5. Each 10 °C increase made the reaction between 1.7 and 2.0 times faster. The results support the hypothesis that higher temperature increases reaction rate, consistent with collision theory. An Arrhenius plot of the sample data gave an estimated activation energy of about 50 kJ/mol.
Introduction
The rate of a chemical reaction depends on how often reactant particles collide and on what fraction of those collisions have enough energy to break existing bonds. According to collision theory, only collisions with energy equal to or greater than the activation energy (Eₐ) lead to a reaction. Raising the temperature increases the average kinetic energy of the particles, so they collide more often and, more importantly, a larger fraction of collisions exceed the activation energy (Flowers et al., 2019, sec. 12.5). The relationship between the rate constant k and the absolute temperature T is described by the Arrhenius equation, k = Ae^(−Eₐ/RT), where R is the gas constant (8.314 J/(mol·K)) and A is a constant for the reaction.
When sodium thiosulfate reacts with hydrochloric acid, one of the products is solid sulfur:
Na₂S₂O₃(aq) + 2HCl(aq) → 2NaCl(aq) + SO₂(g) + S(s) + H₂O(l)
The sulfur forms a fine pale-yellow precipitate that makes the solution increasingly opaque. If the same amounts of reactants are used every time, the same amount of sulfur is needed to hide a mark under the flask, so the reciprocal of the time (1/t) can be used as a measure of the reaction rate.
Research question: How does the temperature of the reaction mixture affect the rate of reaction between sodium thiosulfate and hydrochloric acid?
Hypothesis: If the temperature of the reaction mixture is increased from 20 °C to 60 °C, then the time for the cross to disappear will decrease and the rate (1/t) will increase, because a larger fraction of collisions will have energy above the activation energy.
Variables:
- Independent: temperature of the sodium thiosulfate solution (20, 30, 40, 50, 60 °C)
- Dependent: time for the cross to disappear (s), converted to rate (1/t)
- Controlled: volume and concentration of both solutions, flask size and shape, the cross (same sheet of paper), observer, viewing angle (from directly above)
Materials and Methods
Materials: 0.15 M sodium thiosulfate solution; 1.0 M hydrochloric acid; 250 mL Erlenmeyer flask; 50 mL and 10 mL graduated cylinders; thermometer (±0.5 °C); hot plate and water bath; stopwatch (0.01 s); white paper marked with a black cross; safety goggles.
Safety: Goggles were worn throughout. The reaction releases sulfur dioxide, an irritant gas, so the experiment was carried out in a well-ventilated lab and the flask was not sniffed. Mixtures were disposed of according to the teacher’s instructions.
Procedure:
- 50.0 mL of 0.15 M sodium thiosulfate solution was measured into the flask and warmed in a water bath until it reached the target temperature (±1 °C).
- The flask was placed on the paper so that the cross was directly under its center.
- 5.0 mL of 1.0 M hydrochloric acid was added, the flask was swirled once, and the stopwatch was started at the moment of addition.
- The stopwatch was stopped when the cross could no longer be seen from directly above the flask.
- The temperature of the mixture was recorded immediately after timing.
- The flask was emptied, rinsed with distilled water and dried, and steps 1–5 were repeated for three trials at each of the five temperatures. The same student judged the end point in every trial.
Results
Table 1. Time for the cross to disappear at five temperatures (sample data for illustration)
| Temperature (°C) | Trial 1 (s) | Trial 2 (s) | Trial 3 (s) | Mean time (s) | Range (s) | Relative rate, 1000/t (s⁻¹) |
|---|---|---|---|---|---|---|
| 20 | 68.4 | 71.2 | 69.6 | 69.7 | 2.8 | 14.3 |
| 30 | 35.8 | 34.1 | 36.4 | 35.4 | 2.3 | 28.2 |
| 40 | 18.9 | 17.6 | 18.5 | 18.3 | 1.3 | 54.5 |
| 50 | 10.2 | 9.6 | 10.5 | 10.1 | 0.9 | 99.0 |
| 60 | 5.8 | 6.3 | 5.6 | 5.9 | 0.7 | 169.5 |
The mean time for the cross to disappear decreased at every temperature step, from 69.7 s at 20 °C to 5.9 s at 60 °C. The relative rate increased from 14.3 to 169.5, almost twelve times higher at 60 °C than at 20 °C. The ratio of rates between neighboring temperatures was 1.97 (20 to 30 °C), 1.93 (30 to 40 °C), 1.82 (40 to 50 °C) and 1.71 (50 to 60 °C). The absolute range between trials was largest at 20 °C (2.8 s) and smallest at 60 °C (0.7 s), although as a fraction of the mean time it was similar (about 4% at 20 °C and 12% at 60 °C).
Figure 1 (graph of relative rate against temperature) shows a curve that rises more and more steeply as temperature increases, rather than a straight line. Figure 2 (an Arrhenius plot of ln(1/t) against 1/T, with T in kelvin) shows the five points lying close to a straight line with a negative slope. The slope of the best-fit line was about −6,050 K, which corresponds to an estimated activation energy of about 50 kJ/mol (Eₐ = −slope × R).
Discussion
The results support the hypothesis. As the temperature increased, the time for the cross to disappear decreased at every step and the rate increased. The rate roughly doubled for each 10 °C rise at the lower temperatures, which is a common rule of thumb for reactions near room temperature, but the ratio fell to about 1.7 between 50 and 60 °C. This decrease is expected from the Arrhenius equation: for a fixed activation energy, the same 10 °C step causes a smaller relative change in the exponential term at higher absolute temperatures.
The explanation lies in collision theory. At higher temperatures the particles move faster, so they collide more often, but the more important effect is that a much larger fraction of collisions have energy above the activation energy. That is why the rate increased far more than the small increase in collision frequency alone would predict (Flowers et al., 2019, sec. 12.5). The straight-line Arrhenius plot is further evidence that the reaction follows this model over the temperature range tested.
The activation energy estimate should be treated with caution. It assumes that 1/t is proportional to the rate constant, which is only approximately true, because the end point depends on the observer’s judgment of when the cross is hidden rather than on a measured concentration. The estimate shows the method, not a precise value for this reaction.
Error analysis. The main random error was the judgment of the end point. The cross fades gradually, so deciding exactly when it “disappears” varies from trial to trial. Using one observer and viewing from directly above in all trials reduced this but could not remove it. Reaction time when starting and stopping the stopwatch (about 0.2 s) matters little at 20 °C (0.3% of 69.7 s) but becomes significant at 60 °C (about 3% of 5.9 s), which explains why the relative spread was larger at high temperatures.
The main systematic error was temperature control. The hydrochloric acid was added at room temperature, so the mixture cooled slightly as soon as the acid was added, and the warm flask also lost heat to the air during the reaction. Both effects mean the actual reaction temperature was a little below the target, most of all at 50 and 60 °C. This would make the measured rates at high temperatures slightly too low. Warming the acid to the same temperature in a separate tube before mixing, and recording the temperature at both the start and the end, would improve the experiment. A light sensor or colorimeter measuring the cloudiness would remove the subjective end point entirely.
Conclusion
Increasing the temperature from 20 °C to 60 °C increased the rate of reaction between sodium thiosulfate and hydrochloric acid about twelvefold, with each 10 °C rise making the reaction 1.7 to 2.0 times faster. The hypothesis was supported, and the pattern is consistent with collision theory and the Arrhenius equation. The main limitations were the subjective end point and the drop in temperature after mixing.
References
Flowers, P., Theopold, K., Langley, R., & Robinson, W. R. (2019). Chemistry 2e. OpenStax. Section 12.5, Collision Theory. https://openstax.org/books/chemistry-2e/pages/12-5-collision-theory
Flowers, P., Theopold, K., Langley, R., & Robinson, W. R. (2019). Chemistry 2e. OpenStax. Section 12.2, Factors Affecting Reaction Rates. https://openstax.org/books/chemistry-2e/pages/12-2-factors-affecting-reaction-rates
Why it works: The introduction moves from general theory to the specific reaction and ends with a research question, a hypothesis with a reason, and a clear list of variables. The methods give quantities and the exact end-point rule. The results show every trial, the averages and the spread, and describe the graphs without explaining them. The discussion does three separate jobs: it says whether the hypothesis was supported, explains why with cited theory, and analyzes errors by direction and size. It also flags its own weakest claim (the activation energy) instead of overselling it. The improvements suggested are specific (“warm the acid separately”, “use a colorimeter”), not “be more careful”.
Your own chemistry lab report? Paste your procedure and your own data table into the instructions of the lab report generator, and it writes the introduction, discussion and error analysis around YOUR numbers. It cannot run the experiment for you, so the measurements have to come from your lab. You get a draft to check against your handout and adapt.
Example B: Biology lab report (intro college), catalase activity vs. pH
Level: intro college biology or AP/IB Biology. Experiment: filter-paper disc flotation with potato catalase.
Title
The Effect of pH on the Activity of Catalase Extracted from Potato
Abstract
Catalase is an enzyme that breaks down hydrogen peroxide into water and oxygen. This experiment tested how pH affects the activity of catalase extracted from potato tissue. Filter-paper discs soaked in potato extract were placed in hydrogen peroxide solutions buffered at pH 3, 5, 7, 9 and 11, and the time for each disc to rise to the surface (as oxygen bubbles formed on it) was recorded. Activity, expressed as 1000/t, was highest at pH 7 (75.2) and fell to 22% of that value at pH 3 and 27% at pH 11. Discs soaked in boiled extract did not rise within 300 s. The results support the hypothesis that catalase activity peaks near neutral pH and decreases in strongly acidic and basic conditions, consistent with changes in the shape of the enzyme’s active site.
Introduction
Enzymes are biological catalysts. They speed up reactions by lowering the activation energy, and they do so by binding substrate molecules in a region called the active site. The shape and chemical properties of the active site depend on the enzyme’s three-dimensional structure, which is held together partly by hydrogen bonds and ionic interactions. Changes in pH alter the charges on amino acid side chains, which can change the shape of the active site and reduce the enzyme’s ability to bind its substrate. Extreme pH values can denature the enzyme (Clark et al., 2018, sec. 6.5).
Catalase is found in most cells that are exposed to oxygen, where it protects the cell by breaking down hydrogen peroxide, a harmful byproduct of metabolism:
2H₂O₂ → 2H₂O + O₂
Because the reaction produces oxygen gas, catalase activity can be measured by how quickly oxygen is released. In the disc flotation method, a paper disc carrying the enzyme sinks in hydrogen peroxide solution and then rises as oxygen bubbles collect on it; the faster the reaction, the shorter the time to rise. Other methods measure the height of the oxygen foam produced in a test tube (Iwase et al., 2013).
Research question: How does pH affect the rate at which potato catalase breaks down hydrogen peroxide?
Hypothesis: If the pH of the hydrogen peroxide solution is changed from pH 7 toward more acidic (pH 3) or more basic (pH 11) values, then the time for the disc to rise will increase, because changes in charge on the enzyme’s amino acids will alter the shape of the active site and reduce the rate of substrate binding. Catalase activity is predicted to be highest near pH 7, close to the near-neutral conditions inside most cells.
Variables:
- Independent: pH of the buffered substrate solution (3, 5, 7, 9, 11)
- Dependent: time for the disc to rise to the surface (s), converted to activity (1000/t)
- Controlled: hydrogen peroxide concentration and volume, buffer volume, disc size, soaking and draining time, extract batch, temperature (room temperature, 22 °C)
- Control: discs soaked in extract that had been boiled for 5 minutes (tested at pH 7)
Materials and Methods
Materials: fresh potato; blender; cold distilled water; cheesecloth or coffee filter; filter paper and a 6 mm hole punch; forceps; 3% hydrogen peroxide; buffer solutions at pH 3, 5, 7, 9 and 11; 50 mL beakers; 10 mL graduated cylinders; stopwatch (0.01 s); thermometer; goggles and gloves.
Preparation of extract: 50 g of peeled potato was blended with 100 mL of cold distilled water for 30 s and filtered through cheesecloth. The extract was kept on ice and used within one hour. Half of a 10 mL sample was boiled for 5 minutes and cooled to room temperature for the control.
Procedure:
- For each pH, 10 mL of buffer and 10 mL of 3% hydrogen peroxide were mixed in a clean 50 mL beaker.
- A paper disc was held with forceps, soaked in the extract for 10 s and drained on a paper towel for 5 s.
- The disc was dropped into the beaker. The stopwatch was started when the disc touched the bottom and stopped when it reached the surface.
- Three discs were tested at each pH, each in fresh solution.
- The control was run in the same way at pH 7 using boiled extract. Trials were stopped at 300 s if the disc had not risen.
Results
Table 2. Time for an extract-soaked disc to rise at five pH values, 22 °C (sample data for illustration)
| pH | Trial 1 (s) | Trial 2 (s) | Trial 3 (s) | Mean time (s) | Range (s) | Activity, 1000/t (s⁻¹) | Activity as % of pH 7 |
|---|---|---|---|---|---|---|---|
| 3 | 61.3 | 57.8 | 64.2 | 61.1 | 6.4 | 16.4 | 22 |
| 5 | 25.1 | 23.4 | 26.0 | 24.8 | 2.6 | 40.3 | 54 |
| 7 | 13.2 | 12.6 | 14.1 | 13.3 | 1.5 | 75.2 | 100 |
| 9 | 19.8 | 21.5 | 20.6 | 20.6 | 1.7 | 48.5 | 64 |
| 11 | 48.7 | 52.9 | 45.6 | 49.1 | 7.3 | 20.4 | 27 |
| 7 (boiled extract) | >300 | >300 | >300 | no rise | n/a | ≈0 | ≈0 |
The mean time to rise was shortest at pH 7 (13.3 s) and increased toward both ends of the range. Activity at pH 9 (64% of the pH 7 value) was slightly higher than at pH 5 (54%), and activity at pH 11 (27%) was slightly higher than at pH 3 (22%). Discs soaked in boiled extract sank and did not rise within 300 s in any trial. The range between trials was smallest near the middle of the pH range (1.5 s at pH 7) and largest at the extremes (6.4 s at pH 3, 7.3 s at pH 11).
Figure 3 (graph of activity against pH) shows a single peak at pH 7 with activity falling on both sides, giving an approximately bell-shaped curve that is slightly steeper on the acidic side.
Discussion
The results support the hypothesis. Catalase activity was highest at pH 7 and decreased in both more acidic and more basic solutions. The boiled-extract control produced no measurable activity, which confirms that the oxygen production in the other trials was caused by the enzyme and not by the paper, the buffer or spontaneous breakdown of hydrogen peroxide.
The decrease in activity away from pH 7 can be explained by the effect of hydrogen and hydroxide ions on the enzyme’s structure. At low pH, extra hydrogen ions add positive charge to amino acid side chains; at high pH, side chains lose hydrogen ions. Both changes disrupt the ionic interactions and hydrogen bonds that hold the active site in shape, so fewer substrate molecules are bound and broken down per second (Clark et al., 2018, sec. 6.5). The peak near pH 7 fits the role of catalase inside cells, where conditions are close to neutral.
The data cannot show the exact optimum. Because pH was tested only at intervals of two units, the true optimum could lie anywhere between about pH 6 and pH 8. The slightly higher activity at pH 9 than at pH 5 hints that the optimum may be a little above 7, but the difference is small compared with the spread between trials, so this should not be claimed without testing more pH values in that range. The experiment also does not show whether the loss of activity at pH 3 and pH 11 was reversible or permanent denaturation; returning used enzyme to pH 7 and retesting it would answer that.
Error analysis. The largest source of random error was variation between discs. The amount of extract each disc absorbed depended on how fully it was soaked and drained, and bubbles sometimes stuck to one side, making the disc tilt and rise unevenly. This probably explains the larger spread at pH 3 and pH 11, where the slow reaction gave more time for these differences to matter. Reaction time on the stopwatch (about 0.2 s) was small compared with all mean times.
Possible systematic errors include a gradual loss of enzyme activity in the extract during the hour of testing, which would make later trials slower. Testing the pH values in random order, rather than from pH 3 to pH 11, would spread this effect across all conditions instead of biasing one end. The buffer components themselves may also affect the enzyme slightly differently at each pH. Using a gas syringe or an oxygen sensor to measure the volume of oxygen produced per minute would give a more direct and precise measure of rate than flotation time.
Conclusion
Potato catalase was most active at pH 7 and lost most of its activity at pH 3 and pH 11, falling to 22% and 27% of its maximum. Boiled extract showed no activity. The hypothesis was supported, and the results are consistent with pH-dependent changes in the shape of the active site. Testing more pH values between 6 and 8 would locate the optimum more precisely.
References
Clark, M. A., Douglas, M., & Choi, J. (2018). Biology 2e. OpenStax. Section 6.5, Enzymes. https://openstax.org/books/biology-2e/pages/6-5-enzymes
Iwase, T., Tajima, A., Sugimoto, S., Okuda, K., Hironaka, I., Kamata, Y., Takada, K., & Mizunoe, Y. (2013). A simple assay for measuring catalase activity: A visual approach. Scientific Reports, 3, 3081. https://doi.org/10.1038/srep03081
Why it works: This report adds two things a high-school report often skips: a negative control (boiled extract) and an honest limit on what the data can show. Instead of announcing “the optimum pH of catalase is 7”, the discussion says the optimum lies somewhere between pH 6 and 8 because of the two-unit spacing, and it refuses to over-read a small difference between pH 5 and pH 9. The error analysis links the larger spread at the extremes to a specific cause, and the improvements (random order, gas syringe) target exactly the errors identified. The second reference shows awareness of an alternative method without padding the list.
Biology lab due this week? Give the lab report generator your handout, your variables and the table you recorded in class. It drafts the introduction from textbook-level theory with real references and writes the discussion and error analysis to match your actual results, including the odd trial that did not fit. Check every number against your lab notebook before you submit.
Example C: Physics lab report (high school or intro college), pendulum period vs. length
Level: high school physics or intro college mechanics. Experiment: measuring g from the period of a simple pendulum.
Title
Determining the Acceleration Due to Gravity from the Period of a Simple Pendulum
Abstract
This experiment measured how the period of a simple pendulum depends on its length and used the relationship to calculate the acceleration due to gravity, g. The time for ten oscillations was recorded three times for each of five lengths from 0.200 m to 1.000 m, with a release angle of about 10°. A graph of period squared (T²) against length (L) was a straight line through the origin with a slope of 4.042 s²/m, giving g = 9.77 m/s². This differs from the accepted value of 9.81 m/s² by 0.44%. The difference is consistent with the small systematic effect of the non-zero release angle. The results support the model T = 2π√(L/g).
Introduction
A simple pendulum consists of a small, heavy bob suspended from a light string. When the bob is pulled aside and released, gravity provides a restoring force that makes it swing back and forth. For small angles (below about 15°), the motion is approximately simple harmonic, and the period T, the time for one complete oscillation, is given by
T = 2π√(L/g)
where L is the length from the pivot to the center of mass of the bob and g is the acceleration due to gravity. In this model the period depends only on length and g; it does not depend on the mass of the bob or, for small angles, on the amplitude (Urone & Hinrichs, 2022, sec. 16.4).
Squaring both sides gives T² = (4π²/g)L. A graph of T² against L should therefore be a straight line through the origin with a slope of 4π²/g, which allows g to be calculated from the slope: g = 4π²/slope.
Research question: How does the period of a simple pendulum depend on its length, and what value of g does this relationship give?
Hypothesis: If the length of the pendulum is increased, then the period will increase in proportion to the square root of the length, so that T² is directly proportional to L, as predicted by T = 2π√(L/g). The value of g calculated from the slope is expected to be close to the accepted value of 9.81 m/s².
Variables:
- Independent: length of the pendulum, L (0.200, 0.400, 0.600, 0.800, 1.000 m)
- Dependent: period, T (s)
- Controlled: bob mass (50 g), release angle (about 10°), string type, pivot (clamped)
Materials and Methods
Materials: 50 g steel bob; light inextensible string; clamp stand with a split-cork pivot; meter stick (±1 mm); protractor; stopwatch (0.01 s).
Procedure:
- The string was clamped between two halves of a cork so that the pivot point was fixed.
- The length was adjusted so that the distance from the pivot to the center of the bob was 0.200 m, measured with the meter stick.
- The bob was pulled aside to about 10° using the protractor and released without pushing.
- After the first two swings, the stopwatch was started as the bob passed the lowest point and stopped after ten complete oscillations, again at the lowest point.
- Step 4 was repeated for three trials, and the procedure was repeated for lengths of 0.400, 0.600, 0.800 and 1.000 m.
- The period was calculated as T = (mean time for 10 oscillations) / 10.
Timing at the lowest point was chosen because the bob moves fastest there, so the moment it passes a fixed reference is easiest to judge.
Results
Table 3. Time for ten oscillations at five lengths (sample data for illustration)
| Length L (m) | Trial 1, 10T (s) | Trial 2, 10T (s) | Trial 3, 10T (s) | Mean 10T (s) | Period T (s) | T² (s²) |
|---|---|---|---|---|---|---|
| 0.200 | 9.04 | 8.96 | 9.01 | 9.00 | 0.900 | 0.811 |
| 0.400 | 12.71 | 12.78 | 12.66 | 12.72 | 1.272 | 1.617 |
| 0.600 | 15.58 | 15.51 | 15.62 | 15.57 | 1.557 | 2.424 |
| 0.800 | 17.97 | 18.05 | 17.93 | 17.98 | 1.798 | 3.234 |
| 1.000 | 20.12 | 20.06 | 20.15 | 20.11 | 2.011 | 4.044 |
The period increased with length, from 0.900 s at 0.200 m to 2.011 s at 1.000 m. Increasing the length by a factor of five increased the period by a factor of about 2.23, close to √5 ≈ 2.24. The range between trials was 0.12 s or less for ten oscillations at every length, which corresponds to 0.012 s or less per period.
Figure 4 (graph of T against L) shows a curve that rises steeply at first and then flattens. Figure 5 (graph of T² against L) shows all five points lying on a straight line. The least-squares line of best fit has a slope of 4.042 s²/m and an intercept of 0.0008 s², which is effectively zero.
Calculation of g:
g = 4π² / slope = 39.478 / 4.042 = 9.77 m/s²
Percent error = |9.77 − 9.81| / 9.81 × 100 = 0.44% (calculated from the unrounded value, 9.767 m/s²)
Discussion
The results support the hypothesis. The graph of T² against L is a straight line through the origin, which shows that T² is directly proportional to L and therefore that T is proportional to √L, as the model T = 2π√(L/g) predicts. The value of g calculated from the slope, 9.77 m/s², is within 0.5% of the accepted value of 9.81 m/s².
Using a graph rather than calculating g from each length separately has two advantages. It uses all fifteen measurements at once, so random errors in individual trials partly cancel. It also tests the model itself: if the line had not passed through the origin, that would have pointed to a consistent error in measuring length, such as measuring to the top of the bob instead of its center.
Error analysis. The main random error was reaction time in starting and stopping the stopwatch, estimated at about 0.2 s per reading. Timing ten oscillations reduced this to about 0.02 s per period, and the observed spread between trials (0.012 s per period or less) is consistent with that estimate. The meter stick reading (±1 mm) contributes an uncertainty of 0.5% at 0.200 m but only 0.1% at 1.000 m, so the shorter lengths are the least reliable points.
The measured value of g is slightly low, which suggests a systematic error that makes the measured periods a little too long. The most likely cause is the release angle. The formula T = 2π√(L/g) is exact only for very small angles. At larger amplitudes the period is slightly longer; the standard first correction is a factor of about (1 + θ₀²/16), where θ₀ is the amplitude in radians. For 10° (0.175 rad), this makes the period about 0.19% longer, and because g depends on T², it makes the calculated g about 0.4% too low. This matches the observed difference of 0.44% closely, so the release angle could account for almost all of it. Air resistance and a slight stretch of the string would act in the same direction but are likely to be smaller. The accepted value itself varies slightly with location on Earth’s surface, so a difference of a few hundredths of a m/s² is not significant on its own.
To improve the experiment, the release angle could be reduced to about 5°, which would cut the amplitude effect to roughly a quarter. A light gate connected to a timer would remove reaction-time error. Adding more lengths, especially longer ones, would improve the reliability of the slope.
Conclusion
The period of the pendulum was proportional to the square root of its length, and the slope of the T² against L graph gave g = 9.77 m/s², 0.44% below the accepted value of 9.81 m/s². The hypothesis was supported. The small difference can be explained by the 10° release angle, which makes the period slightly longer than the small-angle formula predicts.
References
Urone, P. P., & Hinrichs, R. (2022). College Physics 2e. OpenStax. Section 16.4, The Simple Pendulum. https://openstax.org/books/college-physics-2e/pages/16-4-the-simple-pendulum
Why it works: The introduction turns the formula into a testable straight-line prediction (T² against L) before any data appear, so the graph does real work: it tests the model and produces g. The calculation is shown with the formula, the numbers and the unrounded value. The error analysis is quantitative. Instead of “there may have been human error”, it estimates the size of each error, checks it against the observed spread, and shows that one systematic effect (amplitude) predicts both the direction and almost exactly the size of the discrepancy. That is the level that earns top marks in the analysis criterion of most rubrics.
Have your pendulum or projectile data? Enter the formula you are testing, your lengths and times or your own data table into the lab report generator. It writes the theory, the calculation steps and a quantitative error analysis based on the numbers you give it. It does not make up measurements; if your data are messy, the discussion says so.
The part most examples skip: references that actually exist
A lab report needs only a few references, usually for the theory in the introduction and discussion. But they have to be real. Lab reports written with general-purpose chatbots often fall down here: the reference list looks tidy but contains textbook editions, page numbers or journal articles that do not exist. Teachers who check one reference and find it fake tend to check everything else. A trustworthy example shows sources you can open:
Clark, M. A., Douglas, M., & Choi, J. (2018). Biology 2e. OpenStax.
Flowers, P., Theopold, K., Langley, R., & Robinson, W. R. (2019). Chemistry 2e. OpenStax.
Iwase, T., Tajima, A., Sugimoto, S., et al. (2013). A simple assay for measuring catalase activity: A visual approach. Scientific Reports, 3, 3081.
Urone, P. P., & Hinrichs, R. (2022). College Physics 2e. OpenStax.
Free open textbooks such as the OpenStax series are a good default for school lab reports: they are written by subject experts, reviewed, and available to anyone, so your teacher can check the section you cite. If your course uses a specific textbook, cite that one instead. Our guide on how to cite sources in academic writing covers APA, which is the style most science teachers ask for, along with MLA and Chicago.
Sources to check: Flowers et al. (2019), Chemistry 2e, sections 12.2 and 12.5; Clark et al. (2018), Biology 2e, section 6.5; Urone & Hinrichs (2022), College Physics 2e, section 16.4 (small-angle limit of about 15°, period independent of mass); Iwase et al. (2013), Scientific Reports 3, 3081.
Lab report template (copy and fill in)
Use this skeleton for any experiment. Delete the prompts in brackets as you replace them.
Title: The Effect of [independent variable] on [dependent variable] in [system or organism]
Abstract (write it last, 100–200 words): [Aim in one sentence.] [Method in one or two sentences.] [Key result with numbers.] [Whether the hypothesis was supported.] [One-sentence explanation.]
Introduction: [Background theory, with at least one citation.] [How the theory applies to this experiment.] Research question: How does [IV] affect [DV]? Hypothesis: If [IV changes in this way], then [DV will change in this way], because [scientific reason]. Variables: Independent: [ ] Dependent: [ ] Controlled: [ ] Control group (if any): [ ]
Materials and Methods: Materials: [list with sizes, concentrations and instrument precision]. Safety: [hazards and precautions]. Procedure: [numbered steps in the past tense, with quantities and exact start/stop points].
Results: Table 1. [Title above the table]: [raw trials, mean, range, processed values with units]. [One paragraph describing the trend, the highest and lowest values, and the spread.] Figure 1. [Caption below the graph: what is plotted against what.]
Discussion: [Was the hypothesis supported? Refer to specific numbers.] [Scientific explanation, with citation.] [Comparison with expected or accepted values, percent error if relevant.] [Random errors: what, how big, evidence from the spread.] [Systematic errors: what, which direction, how big.] [Specific improvements.] [Limits of what the data can show.]
Conclusion: [Answer to the research question in one or two sentences with the key number.] [Hypothesis supported or not.] [Main limitation.]
References: [2–5 sources in the style your teacher requires.]
15 experiments that make a good lab report
These are standard school experiments that give clear, measurable results with simple equipment. Pick one your teacher approves and run it before you write.
| Level | Subject | Experiment (IV → DV) |
|---|---|---|
| Middle / early HS | Biology | Light intensity → rate of photosynthesis (oxygen bubbles from pondweed) |
| Middle / early HS | Chemistry | Surface area (powder vs. chips) → rate of reaction of calcium carbonate with acid |
| Middle / early HS | Physics | Drop height → bounce height of a ball |
| Middle / early HS | Biology | Salt concentration → mass change of potato cylinders (osmosis) |
| Middle / early HS | Chemistry | Type of antacid → mass of acid neutralized |
| High school | Chemistry | Temperature → rate of thiosulfate–acid reaction (Example A) |
| High school | Physics | Pendulum length → period, and g from the slope (Example C) |
| High school | Chemistry | Concentration → rate of reaction (magnesium ribbon in acid) |
| High school | Physics | Resistance and length of a wire (Ohm’s law) |
| High school | Chemistry | Acid–base titration to find an unknown concentration |
| Intro college | Biology | pH → catalase activity (Example B) |
| Intro college | Biology | Temperature → enzyme activity, with an optimum |
| Intro college | Chemistry | Beer–Lambert law: concentration → absorbance (spectrophotometer) |
| Intro college | Physics | Projectile launch angle → range |
| Intro college | Chemistry | Specific heat capacity of a metal by calorimetry |
From example to your own lab report
An example is a frame, not a shortcut. Copy the structure, never the wording or the numbers. The fastest way to write your own report is in this order: Results first (your table and graph are already done in the lab), then Methods (while you still remember what you did), then Discussion, Introduction, Conclusion, and the Abstract last. Writing the introduction first is the most common reason students run out of time, because they write a page of background before they know what their data say.
If the blank page is the problem, a lab report generator can turn your procedure and measurements into a structured first draft with real references in a few minutes. It costs from $2, depending on length. Treat the result the way you would treat a lab partner’s draft: check every number against your notebook, make sure the discussion matches what actually happened at your bench, and rewrite it in your own words where needed. Your teacher’s rules on AI use apply. Some allow drafting tools, some ask you to declare them, and some forbid them for graded work, so check before you start. For longer, source-based assignments that are not experiments, the report generator is the better fit, and the step-by-step guide to writing a report online covers that workflow. If your English class has you writing about books rather than experiments, see our book report examples.
Frequently asked questions
What are the main parts of a lab report?
Most lab reports have a title, abstract, introduction (with research question and hypothesis), materials and methods, results, discussion, conclusion and references. This is the IMRaD structure with a few extra sections. Some high-school templates use “Purpose, Hypothesis, Procedure, Data, Analysis, Conclusion” instead; the content is the same.
Should a lab report be written in past or present tense?
Use the past tense for what you did and what you found (“The solution was heated”, “The mean time was 13.3 s”). Use the present tense for accepted scientific facts and for statements about what your figures show (“Enzymes denature at extreme pH”, “Table 1 shows…”). Never write the procedure as commands.
Can I use “I” or “we” in a lab report?
It depends on your teacher. The traditional convention is the passive voice (“The mass was measured”), and many high-school rubrics still expect it. Many scientists and journals now accept “we” because it is clearer. If you are not told, use the passive in Methods, keep it consistent, and ask before the next report.
How long should a lab report be?
For high school, usually 2 to 5 pages including tables; for intro college labs, 4 to 8 pages. Length should come from analysis, not background. A short introduction and a thorough discussion with real error analysis score better than three pages of textbook theory and two lines of conclusion.
What is the difference between random and systematic error?
Random errors vary unpredictably from trial to trial (reaction time, judging an end point) and show up as spread in your repeated measurements; repeating trials and averaging reduces them. Systematic errors push every measurement in the same direction (a miscalibrated balance, heat loss, a release angle that is too large) and are not reduced by repeating; you have to identify and correct them. A good discussion names both, says which way each pushes the result, and estimates how much.
Can AI write my lab report?
AI can help you draft the sections, explain the theory and structure your error analysis, but it cannot do the experiment, and it should never invent your data. The measurements have to come from your lab work. Use any draft as a starting point, check it against your notebook and your teacher’s rubric, and follow your school’s rules on AI use, which may require you to disclose it.
Summary
A lab report earns its marks in three places: a hypothesis with a scientific reason, a results section that shows every trial clearly, and a discussion that explains the results and analyzes errors by direction and size. The three examples above show those moves in chemistry, biology and physics. Use them as a model for structure, build your own report on your own measurements, and check every reference before you hand it in.
Related articles
How to Write a Report: Structure, Sources and Example (Student Guide)
10 min · June 2, 2026
GuideResearch questions vs hypotheses — when to use which, with examples (2026)
10 min · August 14, 2026
GuideHow to write a results chapter — reporting findings without interpreting (2026)
10 min · July 17, 2026